2 Measuring modes: continuous/single
● 2 Shutdown modes: manual/automatic
● Wide measuring range with 5 probes available (next page)
● Direct testing mode and block statistics mode (APPL/BATCH)
● Can connect with printer to out of statistical values
● Dataview to connect with PC with USB 2.0 port
● 500 datas can be stored
Main features
Can use various probe (F400, F1, F1/90 °, F10, N1, N400, etc.) measurement;
Three calibration methods: one point calibration, two point calibration, the basic calibration;
Display resolution: 0.1 μ m (measuring range of less than 100 μ m)
1μ m (range greater than 100 μ m)
Have five statistics, data storage 500
There are two working methods: direct ways and means of group
There are two measurements: continuous measurement and a single measurement
There are two shutdown: manual and automatic shutdown shutdown
Can be set Bound: The gauge of the measured value can be automatic alarm and a number of measurements available
on the histogram value analysis;
Deleted features: the gross error and error settings can be deleted;
Printing: Print Measurement measurement, statistics, gauges, histogram
A music tone in the operation carried out at any time tips
A power supply under-voltage direct function
An error function
And printers, computer communications (communications software operating environment for
the Window operating system) connectivity.
Technical specifications
Measuring range
|
0-1250μ with standard probe F1.N1 (10.000mm max)
|
Probes available
|
5 probes available for F (ferrous: on steel/iron) and N (non-ferrous metals)
|
Tolerance
|
F1:±(1μ+3%H) N1.±(1.5μ+3% H)
H: actual thickness tested
|
Resolution
|
Alphanumeric with 4 large digits
|
Operation language
|
English
|
Standards
|
DIN, ISO, ASTM,BS
|
Min. measuring area
|
F1:(standard probe)
|
Min. curvature radius
|
convex:3mm, concave:50mm
|
Min. substrate
thickness
|
type F: 0.5mm, type N: 50mm
|
Calibration
|
Zero and foil calibration
|
Statistics
|
Number of measurements, mean, standard deviation,
maximum and minimum of 3000readings
|
Data memory
|
500 measuring data
|
Limits
|
Adjustable with acoustic alarm
|
Interface
|
USB 2.0
|
Operating temperature
|
0-40℃
|
power supply
|
AA size 1.5V
|
Dimensions
|
125*67*31mm (main unit)
|
Weight
|
345.g
|
Standard delivery
Main unit
|
1
|
Probe F1 or N1
|
1
|
Calibration foils
|
5
|
Instruction manual
|
1
|
Cetificate
|
1
|
Warranty card
|
1
|
Carrying case
|
1
|
Communication cable
|
1
|
PC software Dataview
|
1
|
Optional accessories
· 5 probes for different applications
· Calibration foils in various thickness
Option probes for TM510FN
Type F probe :
Type F probe :
Probe
|
F400
|
F1
|
F1/90°
|
F10
|
Measuring Principle
|
Magnetic method
|
Measuring range(mm)
|
0~400
|
0~1250
|
0~10000
|
Min resolution(mm)
|
0.1
|
0.1
|
10
|
Tolerance
|
One-point calibration (mm)
|
±(2%H+0.7)
|
±(2%H+1)
|
±(2%H+10)
|
Two-point calibration (mm)
|
±(1%H+0.7)
|
±((1%H+1)
|
±(1%H+10)
|
Minimum radius of curvature (convex) (mm)
|
1
|
1.5
|
flat
|
10
|
Minimum measuring area(mm)
|
F3
|
F7
|
F7
|
F40
|
Minimum thickness of base material(mm)
|
0.2
|
0.5
|
0.5
|
2
|
|
|
|
|
|
|
|
Type N probe :
Probe
|
N400
|
N1
|
CN02
|
Measuring Principle
|
Eddy current method
|
Measuring range (mm)
|
0~400
|
0~1250
|
10~200
|
Min resolution(mm)
|
0.1
|
0.1
|
1
|
Tolerance
|
One-point calibration (mm)
|
<td style="border-bottom: #333333 1pt solid; padding-bottom: 0cm; padding-left: 2.25pt; width: 84.75pt; padding-right: 2.25pt; border-top-style: none; border-left-style: none; border-right: #33
สินค้าใกล้เคียง |
|